Korg X50 Musical Instrument User Manual


 
Setting the functions of [SW1] and [SW2]
113
Quick StartIntroductionSetupProgram
Combination
MultiEffectGlobalArpeggiatorDrum Kit
Other functions
Setting the functions of
[SW1] and [SW2]
[SW1] and [SW2] are the two switches below the
[PITCH] wheel and [MOD] wheel. These on/off
switches can perform a number of different func-
tions, such as modulating sounds or effects, or
locking the modulation values of the [PITCH]
wheel.
Also, each one may work either as a toggle, or as a
momentary switch. In Toggle mode, each press
alternates between on and off; in Momentary
mode, the switch only changes for as long as you
hold it down.
Use “SW 1/2 Assign” in the following pages to
make these settings.
Each Program, Combination, and Multi set
stores its own settings for what the switches
will do, and whether each switch is on or off
(based on their current states when the data is
saved).
When using SW1/2 for AMS or Dmod, the
default settings are SW1 Mod.(CC#80) and SW2
Mod.(CC#81).
For an example, see “Using the Dmod function
and [SW1] to vary the feedback level” (p.85).
For a complete list of the possible assignments,
see “SW1/2 Assign” (PG p.161).
Note: If you wish to keep these settings after the
power is turned off, you must save the Program,
Combination, or Multi set.
Assigning functions to REAL-
TIME CONTROLS B-mode
knobs [1]–[4]
Here’s how you can assign functions to REAL-
TIME CONTROLS B-mode knobs [1]–[4].
The functions of these knobs in B-mode can be
separately assigned for each program, combina-
tion, and multi set.
You will make these settings in “Knob B Assign”
in the following pages.
The default assignments for knobs 1–4 are
Knob Mod.1 (CC#17), Knob Mod.2 (CC#19),
Knob Mod.3 (CC#20), and Knob Mod.4
(CC#21), respectively. For a complete list of the
possible assignments, see “Knobs 1…4 B
Assign” (PG p.162).
Here’s an example of how to set up knob [1] to
control a Program’s filter and amp EG attack time:
1. Press the [PROG] button to enter Program
mode.
2. Access PROG 7: Ed–Arp/Ctrls, Controls.
Press the [MENU/OK] button, use the
ClickPoint to select “Arp/Controls,” and then
press the center.
3. Choose Knob 1-B “Knob B Assign,” and use the
[VALUE] dial etc. to select F/A Attack (CC#73).
4. Press the REALTIME CONTROLS [SELECT]
button to select B-mode, and turn knob [1] to
control the EG attack for the filter and amp.
Note: If you wish to keep these settings after the
power is turned off, you must save the Program,
Combination, or Multi set.
Mode Page
Program PROG 7: Ed–Arp/Ctrls, Controls
Combination COMBI 7: Ed–Arp/Ctrls, Controls
Multi MULTI 7: Arp/Ctrls, Controls
Mode Page
Program PROG 7: Ed–Arp/Ctrls, Controls
Combination COMBI 7: Ed–Arp/Ctrls, Controls