Solo Safe 77
03D—Owner’s Manual
Solo Safe
The Solo Safe function is used to protect channels from being muted when the MIX-
DOWN SOLO or SOLO IN PLACE mode is used. A safe channel is not muted when
other channels are soloed. The input channels, stereo input channel, effects returns,
and stereo cascade input can be set as safe channels. Solo safe settings are made on the
Solo Setup page.
1. Use the [SOLO SETUP] button to locate the Solo Setup page shown
below.
2. Use the cursor buttons to select the SOLO SAFE CHANNEL switches, and
the [ENTER] button to set them.
If you are using a mouse, simply click the SOLO SAFE CHANNEL switches.
Input channels configured as stereo pairs cannot be set individually.
A channel is set as safe when its SOLO SAFE CHANNEL switch is highlighted.
Two-track Input
The 03D two-track input can be used for confidence monitoring
while recording a stereo mix to a master machine. When the MON-
ITOR OUT SOLO/2TR IN switch is set to SOLO, solo signals are fed
to the monitor out and phones connections. When it is set to 2TR
IN, however, the signal connected to the 2TR IN jacks is output. The
levels of the two-track signal being monitored can be set using the
MONITOR OUT and PHONES LEVEL controls.
The 2TR INs are phono jacks with a –10 dBV nominal input level.
SOLO/ 2TR IN
MONITOR
OUT
R
L
2TR IN
–10dBV
(UNBAL)