Sample Mode
fig.04-06_50
Sampling General (Setup Settings)
Parameter
Value Description
Sampling Type
STEREO L R
Samples in stereo.
MONO MIX Mixes the signals input to L and R, and sample in monaural.
MONO L Samples the L input signal in monaural.
MONO R Samples the R input signal in monaural.
Input Source
ANALOG
Samples from INPUT jacks or MIC IN jack.
USB The sound from USB audio will be sampled.
OPTICAL Samples from OPTICAL IN connector.
COAXIAL Samples from COAXIAL IN connector.
RESAMPL Select this when you wish to resample. The sound that is output to MAIN OUT
L/MONO and R will be sampled.
Trigger Mode
MANUAL
Sampling will begin when you touch <START>.
MIDI Sampling will begin when an external sequencer start message (system real-
time message: FA) is received.
LEVEL Sampling will start when the input signal exceeds the level specified by the
Trigger Level setting.
NOTE Sampling will begin when you play the keyboard or note message is re-
ceived.
Trigger Level
-
–00 dB
Specifies the input level at which sampling will begin when the Trigger Mode
is set to “LEVEL.” The trigger level is shown by the “ ” and “ ” in the
level meter located at the right of the screen.
If Trigger Mode is set to other than “LEVEL,” this parameter has no effect.
Pre Trigger
0–1000 msec
After the selected trigger to start sampling has been received, previously re-
ceived data for the length of time specified here will be included in the sam-
pled data. When the Trigger Mode is set to “LEVEL” and the early portion of
the sample is being lost, you can use this setting to include the early portion.
Pre Gain
-12– +36 dB
Adjusts the input gain. This will apply to the sound that is received from all
input jacks. It will also be applied to the sound being resampled. With posi-
tive (+) values, the gain will be higher than originally, and with negative (-)
values the gain will be lower than originally.