A SERVICE OF

logo

enable
[no] vlan VLAN-ID ipv6 enable
Enable IPv6 on an interface and congures an automatically generated link-local addr.
[no] vlan VLAN-ID vrrp vrid < 1 to 255 > enable
Usage: [no] vrrp vrid <VRID> enable
Description: Enable/disable operation of the virtual router instance.
The default value is 'disabled'.
eui-64
[no] vlan VLAN-ID ipv6 address IPV6-ADDR/PREFIX-LEN eui-64
An IPv6 EUI-64 address that can be automatically congured on any interface
failback
vlan VLAN-ID vrrp vrid < 1 to 255 > failback
Usage: vrrp vrid <VRID> failback
Description: Trigger VR to failback to its congured priority value.
failover
vlan VLAN-ID vrrp vrid < 1 to 255 > failover
Usage: vrrp vrid <VRID> failover [with-monitoring]
Description: Trigger VR to failover to a peer.
If keyword 'with-monitoring' is specied, VR continues
to monitor master VR.
Next Available Option:
with-monitoring -- Trigger VR to failover and continue montior of master VR(p. 753)
fastleave
[no] vlan VLAN-ID ip igmp fastleave [ETHERNET] PORT-LIST
Usage: [no] ip igmp fastleave [ethernet] PORT-LIST
Description: Enables or disables IGMP Fast Leaves. When enabled, as soon as
an IGMP Group Leave has been received on a non-cascaded port,
the switch stops forwarding multicast trafc for that group
to that port.
Does not apply to cascaded ports (see ip igmp forcedfastleave).
When disabled, or when the port is cascaded, the regular IGMP
leave time is used (up to 10 seconds when the switch is not
the IGMP Querier).
The default behavior is for IGMP FastLeaves to be enabled.
This feature is congured for ports on a per-VLAN basis.
[no] vlan VLAN-ID ipv6 mld fastleave [ETHERNET] PORT-LIST
723© 2009 Hewlett-Packard Development Company, L.P.
vlanCommand Line Interface Reference Guide