116
Error Messages
An error message appears in the display when an error in operation occurs, or if an operation cannot be
processed correctly. When this occurs, continue by following the instructions indicated in the error
message.
Display Situation Action
There is a problem with the MIDI cable con-
nected to the XV-2020’s MIDI IN connector or
with an external device. However, this mes-
sage is also displayed when the power for the
external device is turned off.
Check to make sure the MIDI cable is firmly and
properly connected. Otherwise confirm that there is
no short in the MIDI cable (try switching the MIDI
cable to check this).
More MIDI messages were received in a
short time than could be processed correctly.
Reduce the amount of MIDI messages that are trans-
mitted.
A system exclusive message that was re-
ceived had an incorrect check sum value.
Correct the check sum value.
A system exclusive message was not proper-
ly received. Repeated appearance of this
same error message means that there is a
problem with the MIDI message.
Check the content of the received system exclusive
message.
USER data has been damaged. Restore the factory settings with the Factory Reset
procedure.
It is possible that the power has been turned
off for the computer connected to the XV-
2020’s USB connector.
Check the power of the connected computer.
It is possible that a USB cable has been pulled
out or has a short.
Check the USB cable.