Anderson Manufacturing AV-9000 Recording Equipment User Manual


 
Section 4Edition 3
Rev G
4-40
17. Press the to advance to the next parameter, ALARM 2 SAMPLE PERIOD (only seen if Ax2 TYPE is
RATE).
18. Press the to advance to the next parameter, ALARM 2 HYSTERESIS.
NOTE: If RATE Alarm is selected, Hysteresis equals RATE in units/TIME BASE.
19. Press the to advance to the next parameter, ALARM 3 TYPE.
* When CONTROL LOOP OPEN is selected for ALARM TYPE and NON PID is selected for CONTROL TYPE (CONTROLLERS section of
CONFIGURATION), prompt LOOP ALARM TYPE will be displayed.
Press the to change, then to
desired value, then press the .
Press the to change, then to
desired choice, then press the .
Press the to change, then to
desired value, then press the .
Ax2 SAMPLE PERIOD
10 SECONDS
Selections
1 to 9999 seconds
Ax3 ALARM TYPE
OFF
Selections for recorder only
OFF
PROCESS - HIGH
PROCESS - LOW
RATE - RISING
RATE - FALLING
Additional selections for use
with controller option
BAND - WITHIN
BAND - OUTSIDE
DEVIATION - ABOVE
DEVIATION - BELOW
CONTROL LOOP OPEN*
P
R
O
C
E
S
S
V
A
R
I
A
B
L
E
S
Note: Units correspond
to units configured in
Process Variables.
Ax2 HYSTERESIS
3 units
Selections
±
999999
(decimal position = 0)
±
9.9999
(decimal position = 4)