Anderson Manufacturing AV-9000 Recording Equipment User Manual


 
Section 4Edition 3
Rev G
4-80
12. Press the to advance to the next parameter, COMMUNICATIONS MODE (Only seen if the communi-
cations option is present).
13. Press the to advance to the next parameter, COMMS ADDRESS 1 (only seen if SLAVE is selected in
COMMUNICATIONS MODE).
14. Press the to advance to the next parameter, COMM BIT RATE.
I
N
S
T
R
U
M
E
N
T
S
E
T
T
I
N
G
S
COMMS BIT RATE
9600
Selections
9600 4800
2400 1200
Press the to change, then ,
as required to desired choice, then
press the .
COMMUNICATIONS MODE
SLAVE
Selections
SLAVE MASTER* OFF
Press the to change, then to
desired choice, then press the .
COMMS ADDRESS
1
Selections
1 to 247
Press the to change, then to
desired value, then press the .
* NOTE: When Master is selected, the recorder uses the comms address that was previously programmed. No slave unit should use this address. Also, the comms address
parameter will not show up if master is selected, it must be programmed price to the selection of Master.