20. Press the to advance to the next parameter, ALARM 3 TIME BASE (only seen if Ax3 TYPE is RATE).
21. Press the to advance to the next parameter, ALARM 3 SAMPLE PERIOD (only seen if Ax3 TYPE is
RATE).
22. Press the to advance to the next parameter, ALARM 3 HYSTERESIS.
NOTE: If RATE Alarm is selected, Hysteresis equals RATE in units/TIME BASE.
Ax3 TIME BASE
PER SEC
Selections
PER SEC PER MIN
PER HOUR PER DAY
Press the to change, then ,
to desired choice, then press
the .
Press the to change, then to
desired value, then press the .
Press the to change, then to
desired value, then press the .
Ax3 SAMPLE PERIOD
10 SECONDS
Selections
1 to 9999 seconds
P
R
O
C
E
S
S
V
A
R
I
A
B
L
E
S
Note: Units correspond
to Units configured in
Process Variables.
Ax3 HYSTERESIS
3 units
Selections
±
999999
(decimal position = 0)
±
9.9999
(decimal position = 4)