Boss Audio Systems GT-10B Music Pedal User Manual


 
132
Chapter 8 Parameters Guide
By connecting your bass amp’s channel switching jack to the
GT-10B’s AMP CONTROL jack, you can then use Amp Control
to switch the amp channel.
This combining of the GT-10B and the amp channels allows
you to get an even wider variety of distortion sounds.
Since the Amp Control setting is handled as one of the effects
parameters saved to each individual patch, it allows you to
switch bass amp channels with each patch.
To determine how the amp channels are switched when the circuit is open
and closed, refer to the amp owner’s manual, or actually confirm the
sounds by operating the amp.
Note that, depending on the circuitry of the channel switching jack in the
bass amp used, the Amp Control function may not operate.
With Amp Control, not only can you switch amp channels, you can also
use it to switch the amp’s effects on and off, like a footswitch controller.
You can also switch this parameter using [MASTER/PEDAL FX] in the
AMP CONTROL screen.
This effect reduces the noise and hum picked up by bass
pickups. Since it suppresses the noise in synchronization with
the envelope of the bass sound (the way in which the bass
sound decays over time), it has very little effect on the bass
sound, and does not harm the natural character of the sound.
Please connect the noise suppressor in the signal path prior to the
reverberation type effect. This setup will prevent unnatural break of the
reverberation type effect.
AMP CONTROL
Parameter/
Range
Explanation
Amp Control
Off
On
Closed
Bass Amp
(Amp's channel switching jack)
GT-10B
(AMP CONTROL jack)
Open
Bass Amp
(Amp's channel switching jack)
GT-10B
(AMP CONTROL jack)
NS1/NS2 (Noise Suppressor)
Parameter/
Range
Explanation
NS1, NS2 ON/OFF (Noise Suppressor ON/OFF)
Off, On
Switches the noise suppressor effect on/
off. Pressing [MASTER/PEDAL FX]
switches On and Off.
Threshold
0–100
Adjust this parameter as appropriate for
the volume of the noise.
If the noise level is high, a higher setting
is appropriate. If the noise level is low, a
lower setting is appropriate. Adjust this
value until the decay of the bass sound is
as natural as possible.
High settings for the threshold parameter may
result in there being no sound when you play
with your bass volume turned down.
Release
0–100
Adjusts the time from when the noise
suppressor begins to function until the
noise level reaches “0.”
Detect
This controls the noise suppressor based on the volume level for
the point specified in Detect.
Input Input volume from input jack.
NS Input Noise suppressor input volume.
FV Out (Foot
Volume Output)
Volume after passing through Foot
Volume.
STEREO
GT-10B_e.book 132 ページ 2008年2月26日 火曜日 午後3時30分