Boss Audio Systems GT-10B Music Pedal User Manual


 
54
Chapter 4 Playing Sounds
About the Range of a Target’s Change
The value of the parameter selected as the target changes within the range defined by “Min” and “Max,” as set on the GT-10B.
When using an external footswitch, or other controller that acts as an on/off switch, “Min” is selected with Off (CLOSED),
and “Max” is selected with On (OPEN).
When using an external expression pedal or other controller that generates a consecutive change in the value, the value of
the setting changes accordingly, within the range set by the minimum and maximum values. Also, when the target is of an
on/off type, the median value of the received data is used as the dividing line in determining whether to switch it on or off.
When using the footswitch:
When using the EXP Pedal:
When controlling the On/Off target with the
EXP Pedal:
* The range that can be selected changes according to the target
setting.
* When the “minimum” is set to a higher value than the
“maximum,” the change in the parameter is reversed.
* The values of settings can change if the target is changed
after the “minimum” and “maximum” settings have been
made. If you’ve changed the target, be sure to recheck the
“minimum” and “maximum” settings.
Min
Max
Off On
Footswitch
Value
Allowable Parameter
Settings Range
0
127
Degree to
Which Expression
Pedal Is Depressed
EXP Pedal
When the pedal
is fully raised
When the pedal
is fully advanced
Min
Max
Allowable Parameter
Settings Range
0
127
EXP Pedal
When the pedal
is fully raised
When the pedal
is fully advanced
When the pedal
is advanced halfway
Off
On
Value
Degree to
Which Expression
Pedal Is Depressed
About the Range of a Controller’s Change
This sets the operational range within which the value of the setting changes when an EXP Pedal or other controller that
changes the value consecutively is used as the source. If the controller is moved outside the operational range, the value
does not change, it stops at “minimum” or “maximum.”
(Example) With ActRngLo: 40, ActRngHi: 80
* When using a footswitch or other on/off switching controller as the source, leave these at “ActRngLo: 0” and “ActRngHi: 127.”
With certain settings, the value may not change.
0
127
MIN
MAX
Degree to
Which Expression
Pedal Is Depressed
Allowable Parameter
Settings Range
40 80
ActRngLo
EXP Pedal
ActRngHi
When the pedal
is fully raised
When the pedal
is fully advanced
Center
value
40 8060
ActRng
Lo
ActRng
Hi
0
127
EXP Pedal
When the pedal
is fully raised
When the pedal
is fully advanced
Off
On
Value
Degree to
Which Expression
Pedal Is Depressed
GT-10B_e.book 54 ページ 2008年2月26日 火曜日 午後3時30分