Edirol R-4Pro Musical Instrument User Manual


 
35
Recording
You can record sound from both mics connected to R-4 Pro XLR input connectors 3 and 4 and a digital
device connected to the digital input connector.
fig.input-analog.eps
System settings
Press the R-4 Pro [SYSTEM] button.
In 1 Recording Setup, set Input Select to Dig+Ana.
Set the Rec Mode to STEREOx2.
Set the other items in 1 Recording Setup as appropriate for the
recording you want to make.
* For more about system settings, refer to “System setup” (p. 64).
Input level knobs
Adjust the input level.
Use the following to simultaneously record sound from mics and a digital device.
See Adjusting the input level (p. 31).
Record button [REC]
Press the [REC] button to begin recording.
For details on recording standby, refer to “Recording standby” (p. 32).
Limiter
Turn this OFF when recording an audio source whose levels have already been adjusted (in contrast to a
live audio source whose levels might change unpredictably), or if you have already checked the maximum
volume levels that are going to occur.
Turn this ON if you need to prevent clipping (distortion) that might be caused by unexpectedly loud
volumes or strong attacks.
* The limiter and input level [SENS] knob settings are invalid for digital input.
Other settings
If you want to monitor the sound being recorded, connect headphones to the PHONES jack and use the
monitor level knob to adjust the volume.
Adjusting the monitor level knob does not affect the level of the sound actually being recorded.
To play back the recorded sound, refer to “Playing back” (p. 37).
Simultaneously recording sound from connected mics
and a digital device
Channel 1 Digital input L channel The input level and sensitivity cannot be
adjusted with the input level knob.
Channel 2 Digital input R channel
Channel 3 Analog input L channel Input level, SENS knob 3
Channel 4 Analog input R channel Input level, SENS knob 4
DIGITAL OUT
CD player for playback
Microp
h
one
R-4_e_new.book 35 ページ 2006年11月20日 月曜日 午後1時9分