Agilent Technologies L4400 Guitar User Manual


 
122 L4400 User’s Guide
5 L4433A Dual/Quad 4x8 Reed Matrix
34933T-001 Terminal Block for Two-Wire Mode
This terminal block with screw- type connections is labeled with the model
number and the abbreviated module name.
NOTE
All modules that connect to the analog bus are interlock protected.
This means that when an installed module is exposed (no terminal
block or cable is connected), the analog bus relays, which are on
Matrix 2, are open and disconnected from the analog buses. See
page 112 for further information.
NOTE
If you are using an Agilent terminal block to connect your DUT to
this module be sure to use the 34933T-001 terminal block that
corresponds to the 2-wire configuration mode. Note that an error
will not be generated if you have installed a terminal block that
doesn't match the present module configuration.