Extron electronic MGP 464 DI DJ Equipment User Manual


 
Operation, cont’d
MGP 464 • Operation
3-4
PRELIMINARY
6 feet
(1.8 m)
Part #70-335-01
9DBF-2.5mm TRS cable_031504.eps
5
1
9
6
Sleeve (Gnd)
Ring
Tip
9-pin D Connection TRS Plug
Pin 2 Computer's RX line Tip
Pin 3 Computer's TX line Ring
Pin 5 Computer's signal ground Sleeve
2.5 mm connector cable for the configuration port (part #70-335-01)
See chapter 4, “Software Conguration and Control,” for details about using
the conguration software and the SIS commands to congure the MGP.
Power-up and Default Cycle
When you rst plug the MGP 464 into a power source, the LCD screen displays a
series of initial messages, followed by the default cycle of screens. These messages
continue to cycle on the LCD screen when the menu system is not in use. The
following flow diagram shows the order in which these screens appear.
Default Cycle
Multi-Graphic
Processor
2 sec.
Window 1 DVI
000.0 kHz 000.0 Hz
Window 2 RGB
000.0 kHz 000.0 Hz
2 sec.
Output Rate
1280 x 1024 @ 60 Hz
2 sec.
Extron
MGP 464DI V1.00
Power
on
Extron
MGP 464 V1.00
2 sec.
Window 3 RGB
000.0 kHz 000.0 Hz
2 sec.
Window 4 RGB
Freeze Enabled
2 sec.
2 sec.
Default cycle
N
From any menu or submenu, the MGP 464 saves all adjustment settings and