Panasonic KX-TVM50 Recording Equipment User Manual


 
5.3 KX-TDA Series PBX Programming for Inband Integration
168 Installation Manual
b) Program the PBX so that unanswered calls to the ICD group are redirected to the VPS (ICD
Group Overflow feature).
1) Go to the "Groups-Incoming Call Distribution Group-Group Settings" screen.
2) Assign "Time out & Manual Queue Redirection-Destination" for the ICD group to a
floating extension number (VPS Port).
3) Assign "Overflow Time" parameter.
4) Click "Apply" to save the changed data.