Panasonic KX-TVM50 Recording Equipment User Manual


 
2.1 Before Installation
32 Installation Manual
2.1 Before Installation
Please read the following precautions before installing the VPS.
Installation Precautions
The VPS should be wall-mounted. Improper placement of the system may result in malfunction,
noise, or discolouration. Avoid installing the VPS in the following places:
in direct sunlight; in hot, cold, or humid places
in areas where sulphuric gas can damage the equipment (e.g., areas near thermal springs, etc.)
where shocks or vibrations are frequent or strong
in dusty places or places where water or oil may come in contact with the unit
near high frequency generating devices such as sewing machines, elevators or electric welders
on or near computers or other office equipment, microwave ovens, or air conditioners (Ideally,
the VPS should not be installed in the same room with any of these items, and should be at least
2 m away from televisions.)
Do not obstruct the areas around the PBX and the VPS. Both require open space above the unit
for cooling and space on the sides for maintenance and inspection.
Wiring Precautions
Be sure to follow these instructions when wiring.
Do not wire the telephone cable parallel to an AC power source, computer, etc. If cables are run
near those wires, shield them with metal tubing or use shielded cables and earth the shields.
Use protectors if running cables on the floor. Avoid running cables under carpets.
Avoid sharing the power supply to the VPS with computers or other office equipment. Induction
noise from such equipment may interrupt the VPS operation.
When making any connections or removing the cover, be sure the power switch is turned off.
When installing telephone wiring, basic safety precautions should always be followed to reduce the
risk of fire, electric shock and injury to persons, including the following:
Never install telephone wiring during a lightning storm.
Never install telephone jacks in wet locations unless the jack is specifically designed for wet
locations.
Never touch uninsulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.
Use caution when installing or modifying telephone lines.
Note
If you live in an area that has frequent power failures, we strongly recommend connecting
the VPS and PBX to an uninterruptible power supply (UPS). Use only a UPS which can
provide adequate power supply to all connected devices. Refer to the specifications for the
power rating of your VPS and PBX.