Panasonic SX-KN7000 Musical Instrument User Manual


 
Control Messages
Enable or disable the exchange of various control data.
1. On the MIDI MENU display, select CONTROL
MESSAGES.
The display looks similar to the following.
The CONTROL MESSAGES display consists
of 3 pages. Use the PAGE buttons to switch
between pages.
2. Use the MESSAGE and buttons to select
the control message.
3. Use the ON and OFF and buttons to
specify on or off for the control message.
ON:
Data for the control operation is exchanged.
OFF:
Data for the control operation is not ex-
changed.
The BANK SELECT setting is effective only
when PRG. CHANGE is set to ON.
The EFFECT & REVERB setting controls the
DIGITAL EFFECT, SOUND DSP, CHORUS,
MULTI and REVERB on/off.
RPN is the general term for KEY SHIFT,
TUNING, PITCH BEND RANGE and MODU-
LATION SENSITIVITY.
4. Repeat steps 1 and 2 for each control as
desired.
Realtime Messages
Enable or disable the exchange of START/STOP data (REALTIME COMMANDS), and select the CLOCK
mode.
1. On the MIDI MENU display, select REALTIME
MESSAGES.
The display looks similar to the following.
2. Use the buttons on the left side of the display
to select a function.
3. Use the VALUE and buttons to change
the setting.
REALTIME COMMANDS
ON:
Rhythm and SEQUENCER start/ stop, con-
tinue, and song position pointer data can
be transmitted/received.
OFF:
This data cannot be transmitted/received.
CLOCK
INTERNAL:
This instruments internal clock is used to
control the performance. The clock of the
connected equipment is disabled.
MIDI:
The clock of the connected equipment is
used to control the performance. This in-
struments clock is disabled. (The tempo is
displayed as = – – .”)
The CLOCK is set to INTERNAL when the
power to this instrument is turned on.
4. Repeat steps 2 and 3 for the other function if
desired.
MIDI
Part XIII MIDI
191
QQTG0671