Panasonic SX-KN7000 Musical Instrument User Manual


 
Quantize
The QUANTIZE function can correct the timing
of your performance after it has been recorded.
If the rhythm is slightly out of sync or inexact, it
will automatically be corrected to the specified
quantize level.
1. On the SEQ MENU display, select RECORD
& EDIT.
2. On the RECORD & EDIT display, select
QUANTIZE.
The display looks similar to the following.
3. Use the TRACK and buttons to specify
the track number.
You cannot select the track for the CONTROL,
RHYTHM or CHORD part.
If ALL is selected, all the tracks are quantized.
4. Use the FIRST MEASURE and buttons
to specify the start point (measure number).
5. Use the LAST MEASURE and buttons to
specify the end point (measure number).
6. Use the VALUE and buttons to specify
the quantize level.
Select from , ,
3,
,
3,
,
3. (A 3 denotes a
triplet-type note.)
7. Use the STRENGTH and buttons to select
the amount of quantize (%).
100% is a convenient setting. When set to
100%, the performance data is quantized ex-
actly to the level specified for the VALUE
(“just). For example, at 50%, the data is quan-
tized to a point that is half that of the just level.
By this setting, you can attain an effect that is
very slightly off-beat from the rhythm.
8. Use the WINDOW and buttons to specify
the range (%) affected by the quantize setting.
With the increment set to 100 for the VALUE,
at a + setting, data close to the just point is
corrected, and at a setting, data far from the
just point is corrected. For example, if set to
30% the quantize function affects data far
from the just point, and if set to +30% the
quantize function affects data close to the just
point. +100% is usually a convenient setting.
The +100% setting and the 100% setting are
the same.
Example: When VALUE is set to
9. Press the OK button.
The confirmation display appears. Press the
YES button to execute the function, or press
the NO button to cancel the function.
Rhythm as written
in the score
Quantized
performance
Timing of actual
performance
100%
50%just
50%
100%
+100%
+50%
+30%
–50%
–30%
–100%
Sequencer
Part IV Sequencer
96
QQTG0671