MMC SETUP
169
MMC SETUP
This page allows separate MMC device IDs to be assigned for MMC transmit and MMC Receive.
Pressing MMC shows this page:
SEND ID sets the MMC ID for transmission - this should match the ID of the machine you
want to control. ID 127 is "Broadcast" to all connected MMC machines.
RECEIVE ID sets the MMC ID for control by external machines. The setting here should
match the MMC ID of the controlling device.
It is possible to nominate whether the DPS24 is an MMC master or slave using the MASTER/
SLAVE parameter.
v1.6 Operator’s Manual