Chapter 5: Management with the CLU
141
Auto Rebuilding: On Hot Spare Policy: Global
Priority: High(RBLD), High(SYNC), High(Migration), High(RC), High(PDM)
--------------------------------------------------------------------------
Disk Array 1 Properties
1. Create Logical Drive
2. Delete Logical Drive
3. Cache Policy
4. Retry Count
5. Enable/Disable SMART
6. Name
7. Priority
8. Hot Spare
9. Auto Rebuilding
R. Return to Previous Menu
Please enter your menu choice>8
5. From this submenu, press 8 and Enter to access the Hot Spare Policy
function.
Current hot spare policy:
Global
Change to Dedicated hot spare policy for LD 1(y/n)?>y
6. Press Y and Enter to change the Hot Spare Policy to Dedicated.
The physical drives selection appears.
*********Physical Drives Selection*********
ID Name Capacity
-------------------------------------------------------
9 WDC WD1200JD-00FYB0 120 GB
11 ST380013AS 80 GB
12 WDC WD1200JD-00FYB0 120 GB
Enter Physical Drive ID to select.
Press R to continue after you have finished
selecting Physical Drive.
Your input?>9
7. From this submenu, press 9 and Enter to select the disk drive ID 9.
The previous screen reappears with disk drive ID 9 selected.
*********Physical Drives Selection*********
ID Name Capacity
--------------------------------------------------------
* 9 WDC WD1200JD-00FYB0 120 GB