Promise Technology 15110 Musical Instrument User Manual


 
VTrak 15110 User Manual
182
Maintenance Menu (Disk Array Operations)
From the Main Menu, press 6 and Enter to access the Maintenance menu:
Maintenance activity Monitor: Running
ID Name RAID SBS CAP Operation Progress
-------------------------------------------------------------------------
1 LogDrv1 5 64K 239GB RBLD 27% on 9
2 LogDrv2 3 64K 265GB None N/A
-------------------------------------------------------------------------
Maintenance
1. Maintenance Activity Monitor
2. Migrate Disk Array
3. Manual Rebuild
4. Manual PDM)
5. Synchronization
6. Redundancy Check
7. Media Patrol
R. Return to Previous Menu
The current Operation is reported for each disk array as follows:
INIT – Initialization, done at logical drive creation. The logical drive is
clearing old, unusuable data from the disk drives.
RBLD – Rebuild, a repair operation. The disk array is rebuilding data or
parity to a replacement drive. The target disk drive is cited by ID number.
The disk array is available
SYNC – Synchronization, a maintenance operation. The disk array checks
the data and parity and corrects inconsistencies. The disk array is available
PDM – Predictive Data Migration, a maintenance operation. The disk array
moves data from a suspect disk drive to a replacement. The target disk drive
is cited by ID number. This action anticipates and prevents a disk drive
failure and resulting Critical Status. A replacement disk drive is required. The
disk array is available
RC – Redundancy Check. The disk array is checking data to verify that
redundancy or parity match. Unlike Synchronizing, no corrections are made.
The disk array is available
MP – Media Patrol. The disk array is checking disk drives to verify the
condition of the magnetic media. Unlike Synchronizing, no corrections are
made. The disk array is available