Promise Technology 15110 Musical Instrument User Manual


 
VTrak 15110 User Manual
142
11 ST380013AS 80 GB
12 WDC WD1200JD-00FYB0 120 GB
Enter Physical Drive ID to select.
Press R to continue after you have finished
selecting Physical Drive.
Your input?>r
8. Press R to finish your selection and press Enter.
The Disk Array Properties submenu displays. Note that Hot Spare Policy has
changed to Dedicated with the physical drive 9 (PD9) as the hot spare.
Stripe Block Size: 64K
Disk Array #1 Mapping: GB
-----------------------------------
| 100 GB | 100 GB | 39 GB |
-----------------------------------
--------------------------------------------------------------------------
Name: Daniels Array
RAID Level: 5 Member LDs: 1-2
Stripe Block Size: 64K Capacity: 240 GB
Member PDs: 1,3-4,7 SMART Check: On
Cache Policy: Write Through Retry Count: 2
Auto Rebuilding: On Hot Spare Policy: Dedicated(PD9)
Priority: High(RBLD), High(SYNC), High(Migration), High(RC), High(PDM)
--------------------------------------------------------------------------
Disk Array 1 Properties
1. Create Logical Drive
2. Delete Logical Drive
3. Cache Policy
4. Retry Count
5. Enable/Disable SMART
6. Name
7. Priority
8. Hot Spare
9. Auto Rebuilding
R. Return to Previous Menu
Please enter your menu choice>
This concludes the example.
CLU Function Map
The map below is designed to help you navigate to the submenu where each
function is located. The paths in this map do not activate the functions.