A SERVICE OF

logo

1-6 Printer Description
EN
Site Requirements
The following environmental specifications must be maintained to
ensure the proper operation of the printer. Consider the following
points before installing the printer:
Install in a well-ventilated, dust-free area.
Install on a hard, flat and continuous surface, with all four printer
feet level. Do not install on carpet or other soft surfaces.
Ensure adequate power is supplied. Printer power requirements
are listed in Table 1-3.
Install where temperature and humidity is stable, away from water
sources, humidifiers, air conditioners, refrigerators, or other major
appliances.
Install away from direct sunlight, open flames, or ammonia fumes.
If the printer is placed near a window, make sure the window has
a curtain or blind to block any direct sunlight.
Install with enough space around the printer for proper access
and ventilation.
Install printer away from the direct flow of exhaust from air
ventilation systems.
Table 1-3. Electrical Specifications
Volts Frequency Amps Watts (typical)
100-127 VAC±10% 50/60 Hz ±3Hz 11 amps printing = 365
standby = 40
PowerSave On = 27 (EPA
E
NERGY
S
TAR
®)
220-240 VAC±10% 50/60 Hz ±3Hz 5 amps printing = 355
standby = 40
PowerSave On = 22 (EPA
E
NERGY
S
TAR
®)