Chapter 7 Saving a Sound You Create
Protecting the Internal
Memory (PROTECT)
This feature helps prevent the accidental overwriting of
USER memory to ensure that Patch, Performance or Rhythm
Set data is not accidentally erased.
fig.7-10
Internal (Internal Write Protect)
The Internal Write Protect setting prevents the Write
operation from accidentally overwriting USER memory
locations. When this is set ON, the data cannot be written.
Data can be only written when Internal Write Protect is off.
When the XV-3080’s power is turned on, this setting is
automatically turned on, – you will need to turn it off before
writing data to the USER memory. It is also possible to turn
this setting off during the Write procedure.
Exclusive (Exclusive Protect)
The Exclusive Protect setting prevents System Exclusive
messages received from an external MIDI device from
rewriting USER memory settings. When this feature is on,
the data cannot be rewritten by System Exclusive messages.
When it is off, data can be rewritten, even if the Internal
Write Protect setting is set to ON.
1. Press [UTILITY] to make its indicator light.
2. Press [ ] or [ ] to select the UTIL 1 page.
3. Use [ ] or [ ] to make “PROTECT” blink, and
then press [ENTER].
4. Press [ ] or [ ] to move the cursor beneath the
parameter you wish to set.
5. Press [INC] to switch the parameter on; press [DEC] to
switch it off.
6. Press [EXIT] to return to the previous page.
Restoring All Settings to
Their Defaults
This function resets all the XV-3080’s settings to their factory
default values.
This operation clears the contents of the USER memory. If
you wish to preserve any of its contents, you must save them
on a commercially available memory card (p. 125) or to an
external sequencer (p. 127) or storage device before
performing the Factory Reset.
1. Press [UTILITY] to make its indicator light.
2. Press [ ] or [ ] to select the UTIL 2 page.
3. Use [ ] or [ ] to make “FACTORY RESET” blink.
4. Press [ENTER].
The FACTORY RESET page appears.
5. Press [ENTER].
“Are You Sure?” appears.
6. If you’re ready to proceed, press [ENTER], and the
Factory Reset operation will be executed.
“Executing...” appears in the display, followed by
“COMPLETED.” You are then returned to the PATCH PLAY
page.
* If you wish to cancel the Factory Reset, press [EXIT] in Step 6.
* If Internal Write Protect is turned ON, the following display
will appear, and the Factory Reset operation will not be
executed.
fig.7-11
Change the displayed ON to OFF and press [ENTER] to turn
Internal Write Protect off.
“Are You Sure?” will be displayed. Press [ENTER].
The Rhythm Set Initialize operation can also be used to
initialize the settings of only an individual percussion
instrument sound (key) that you specify. In this case,
move the cursor to Key, and select the percussion
instrument sound that you wish to initialize. You can
specify the percussion instrument sound by pressing [E]-
[H]. (p. 112)
fig.7-08