Roland XV-3080 Musical Instrument User Manual


 
134
Chapter 8 Other Settings and Checking Status
Making Overall Settings
The following three overall settings can be made.
Adjusting the Display Brightness
LCD (LCD Contrast) 110
This adjusts the contrast/brightness of the display. Higher
values will make the characters darker.
Setting the State of the XV-3080
When Its Power Is Turned On
PowerUp (Power Up Mode)
This sets the condition of the XV-3080 when its power is
turned on.
DEFAULT: The XV-3080 will be ready to play Patch
USER:001.
LAST:The XV-3080 will power up exactly as it was when it
was turned off.
Setting What Happens to Notes
When a New Patch or Rhythm
Set is Selected
Patch Remain (Patch remain switch)
This specifies whether you want the notes that are sounding
to remain (ON) or turn off (OFF) when you select a new
Patch or Rhythm Set in Patch mode.
In addition, when ON is selected, the Volume and Pan
data, and the PATCH KEY MODE and other settings
received via MID are passed on. For details, refer to the
MIDI Implementation (p. 173).
Use the following procedure to perform the three actions
listed above.
1. Press [SYSTEM] to make its indicator light.
2. Press the [SETUP] function select button (displayed in
gray) to make its button indicator light.
3. Use [ ]/[ ] to select the page containing the
parameter you wish to set.
4. Use [ ]/[ ] to move the cursor to the parameter.
5. Use the VALUE dial or [INC] / [DEC] to select the
desired value.
6. Press [EXIT] to return to the previous page.
Confirming the Current
Conditions (INFO)
On this display, you can view the names of the installed
Wave Expansion Boards and check the status of the XV-
3080s internal battery.
INFO EXP (Information Expansion
Board)
The display shows the names of Wave Expansion Boards
installed in slots EXP AF.
Slots without any boards installed are shown as ----------------.
BATTERY CHECK
The XV-3080 contains a battery that retains the data in its
internal memory when the units power is turned off. This
display allows you to check the battery voltage. If the display
says OK, there is sufficient voltage. If the display says
LOW, the battery voltage has run down. Contact your
nearby Roland service station as soon as possible to have the
battery replaced.
The following procedure is used for both purposes.
1. Press [SYSTEM] to make its indicator light.
2. Press the [INFO] function select button (displayed in
gray) to make its button indicator light.
3. Press [ ] / [ ] to select the screen containing the
parameter you want to check.
4. Press [EXIT] to return to the previous page.