Roland XV-3080 Musical Instrument User Manual


 
177
MIDI Implementation
Appendices
7FH Device ID (Broadcast)
09H Sub ID#1 (General MIDI Message)
02H Sub ID#2 (General MIDI Off)
F7H EOX (End Of Exclusive)
* When this messages is received, this instrument will return to the Performance mode.
Universal Realtime System Exclusive Messages
Master Volume
Status Data byte Status
F0H 7FH, 7FH, 04H, 01H, llH, mmH F7H
Byte Explanation
F0H Exclusive status
7FH ID number (universal realtime message)
7FH Device ID (Broadcast)
04H Sub ID#1 (Device Control messages)
01H Sub ID#2 (Master Volume)
llH Master Volume lower byte
mmH Master Volume upper byte
F7H EOX (End Of Exclusive)
* The lower byte (llH) of Master Volume will be handled as 00H.
* The Master Level parameter (SYSTEM/COMMON) will change.
Master Fine Tuning
Status Data byte Status
F0H 7FH,7FH,04H,03H,llH,mmH F7H
Byte Explanation
F0H Exclusive status
7FH ID number (universal realtime message)
7FH Device ID (Broadcast)
04H Sub ID#1 (Device Control)
03H Sub ID#2 (Master Fine Tuning)
llH Master Fine Tuning LSB
mmH Master Fine Tuning MSB
F7H EOX (End Of Exclusive)
mm, ll : 00 00H - 40 00H - 7F 7FH (-100 - 0 - +99.9 [cents])
* The Master Tune parameter (SYSTEM/COMMON) will change.
Master Coarse Tuning
Status Data byte Status
F0H 7FH,7FH,04H,04H,llH,mmH F7
Byte Explanation
F0H Exclusive status
7FH ID number (universal realtime message)
7FH Device ID (Broadcast)
04H Sub ID#1 (Device Control)
04H Sub ID#2 (Master Coarse Tuning)
llH Master Coarse Tuning LSB
mmH Master Coarse Tuning MSB
F7H EOX (End Of Exclusive)
llH : ignored (processed as 00H)
mmH : 28H - 40H - 58H (-24 - 0 - +24 [semitones])
* The Master Key Shift parameter (SYSTEM/COMMON) will change.
Global Parameter Control
* Not received in Performance mode and Patch mode.
Reverb Parameters
Status Data byte Status
F0H 7FH,7FH,04H,05H,01H,01H,01H,01H, F7H
01H,ppH,vvH
Byte Explanation
F0H Exclusive status
7FH ID number (universal realtime message)
7FH Device ID (Broadcast)
04H Sub ID#1 (Device Control)
05H Sub ID#2 (Global Parameter Control)
01H Slot path length
01H Parameter ID width
01H Value width
01H Slot path MSB
01H Slot path LSB (Effect 0101: Reverb)
ppH Parameter to be controlled.
vvH Value for the parameter.
pp=0 Reverb Type
vv = 00H Small Room
vv = 01H Medium Room
vv = 02H Large Room
vv = 03H Medium Hall
vv = 04H Large Hall
vv = 08H Plate
pp=1 Reverb Time
vv = 00H - 7FH 0 - 127
F7H EOX (End Of Exclusive)
Chorus Parameters
Status Data byte Status
F0H 7FH,7FH,04H,05H,01H,01H,01H,01H, F7H
02H,ppH,vvH
Byte Explanation
F0H Exclusive status
7FH ID number (universal realtime message)
7FH Device ID (Broadcast)
04H Sub ID#1 (Device Control)
05H Sub ID#2 (Global Parameter Control)
01H Slot path length
01H Parameter width
01H Value width
01H Slot path MSB
02H Slot path LSB (Effect 0102: Chorus)
ppH Parameter to be controlled.
vvH Value for the parameter.
pp=0 Chorus Type
vv=0 Chorus1
vv=1 Chorus2
vv=2 Chorus3
vv=3 Chorus4
vv=4 FB Chorus
vv=5 Flanger
pp=1 Mod Rate
vv= 00H - 7FH 0 - 127
pp=2 Mod Depth
vv = 00H - 7FH 0 - 127
pp=3 Feedback
vv = 00H - 7FH 0 - 127
pp=4 Send To Reverb
vv = 00H - 7FH 0 - 127
F7H EOX (End Of Exclusive)
Channel Pressure
Status Data byte Status
F0H 7FH,7FH,09H,01H,0nH,ppH,rrHF7H
Byte Explanation
F0H Exclusive status
7FH ID number (universal realtime message)
7FH Device ID (Broadcast)
09H Sub ID#1 (Controller Destination Setting)
01H Sub ID#2 (Channel Pressure)
0nH MIDI Channel (00 - 0F)
ppH Controlled parameter
rrH Controlled range
pp=0 Pitch Control
rr = 28H - 58H -24 - +24 [semitones]
pp=1 Filter Cutoff Control
rr = 00H - 7FH -9600 - +9450[cents]
pp=2 Amplitude Control
rr = 00H - 7FH 0 - 200%