Yamaha 02R96 Musical Instrument User Manual


 
Assigning Parameters to Control Changes 167
02R96—Owner’s Manual
Assigning Parameters to Control Changes
02R96 parameters can be assigned to MIDI Control Changes for real-time control. When a
parameter is adjusted on the 02R96, the assigned Control Change message is transmitted.
Likewise, when a Control Change message is received, the assigned 02R96 parameter is set.
You must set the MIDI Setup parameters in order to transmit and receive Control Change
messages (see page 165).
A Parameter to Control Change assignment table, listing the initial assignments, is provided
on page 274. This table can be stored to an external MIDI device, such as a MIDI data filer,
by using MIDI Bulk Dump (see page 168).
1 Use the DISPLAY ACCESS [MIDI] button to locate the Control Change Assign
Table page.
2 Use the cursor buttons to select the MODE TABLE button, and press [ENTER].
In TABLE mode, when 02R96 parameters are adjusted, MIDI Control Change messages are
transmitted in accordance with the assignments on this page. In NRPN mode, when 02R96
parameters are adjusted, predefined NRPNs (Non Registered Parameter Number) are
transmitted.
3 Use the cursor buttons to select the CTL CHG. column, and use the Parameter
wheel or INC/DEC buttons to select the Control Changes.
4 Use the cursor buttons to select the three PARAMETER columns, and use the
Parameter wheel or INC/DEC buttons to select the parameters.
Parameters with more than 128 steps require two or more Control Change messages for
MIDI transmission and reception. Certain Delay parameters and the faders are divided into
L and H parameters. Delay Time parameters are divided into LOW, MID, and HIGH
parameters. For accurate transmission, all parameters (e.g., both L and H for faders) must
be assigned to individual Control Changes.
You can initialize the Parameter to Control Change assignment table by selecting the INI-
TIALIZE button, and then pressing [ENTER].
Controlling Parameters by Using Parameter Changes
02R96 parameters can be controlled in real time by using Parameter Change messages,
which are System Exclusive messages. When a parameter is adjusted on the 02R96, a Param-
eter Change message is transmitted. Likewise, when a Parameter Change message is
received, a 02R96 parameter is adjusted. See “MIDI Data Format” on page 275 for detailed
information. You must set the MIDI Setup parameters in order to transmit and receive
Parameter Change messages (see page 165).