Patch Change When transmitted: Transmits the patch number. DATA: Patch Number
When received: Changes the Patch. DATA: Patch Number
Data size is fixed at 2 bytes.
Upon receiving RQ1, the GS-10 replies with the patch number.
Request size to the GS-10 at this time is fixed at 2 bytes (set at 00 00 00 02).
Patch Write When received: After the patch is written, the patch is switched to the received patch number, and the Current Patch is output.
Current Patch When received: Current patch number is transmitted (only when RQ1 is received).
Patch When transmitted: DATA: 01H is transmitted.
Initialize When received: Initial value is set if DATA: 01H is received.
Data size is fixed at 1 byte.
AMP Ch Copy When transmitted: Copy-destination amp channel is transmitted.
When received: Copy-destination amp channel is received.
Data size is fixed at 1 byte.
Quick Fx Number When transmitted: Quick Fx number is transmitted. DATA: Quick Fx Number
When received: Quick Fx number is changed. DATA: Quick Fx Number
Data size is fixed at 1 byte.
Quick Fx Count Number of Quick Fx in each Effect block.
Request size is fixed at 1 byte (set at 00 00 00 01).
TUNER/METER Mode 01H: TUNER Mode
02H: METER Mode
00H: exit (Play Mode)
* In TUNER mode: Pitch, Note data transmitted.
* In METER mode: METER POINT data transmitted.
During TAP operations: Delay Time, Delay Time (Fine) transmitted (when setting BPM: Master BPM transmitted).
* The GS-10 can use two methods of communication; Individual Parameter and Bulk Dump.
* Bulk data can be received when the Bulk Load Ready function is accessed in “MIDI:Bulk Load” screen (System mode).
* Although individual data can be received at any time, be sure to appropriately describe the value for one parameter in one packet [F0...F7].
* Do not use an address appended with “#” as the first address.
* Do not specify an odd-number address for Quick Fx Data, SYSTEM:MIDI Program Map.
* Parameters for which Size is 2 or higher should not be separated; make sure these are sent in the same packet.
* Parameters with Size of 2 or higher transmitted from the specified addresses in sequence, from MSB to LSB.
* Output of Quick Fx Name and EFFECT CHAIN is fixed as 12 bytes.
Table TUNER <TUNER>
--------------------------------------------------------------------------------------------------------------
Address(H) Size(H) Data(H) Parameter Description
--------------------------------------------------------------------------------------------------------------
00 00 00 00 00 00 00 01 00 - 0A TUNER Pitch 00 : 435Hz
01 : 436Hz
:
0A : 445Hz
00 00 00 01 00 00 00 01 00 - 01 TUNER Out 00 : Mute
01 : Bypass
Table OUTPUT <SYSTEM: OUTPUT SELECT>
--------------------------------------------------------------------------------------------------------------
Address(H) Size(H) Data(H) Parameter Description
--------------------------------------------------------------------------------------------------------------
01 00 00 00 00 00 00 01 00 - 04 OUTPUT Select 00 : LINE/PHONES
01 : COMBO AMP
02 : STACK AMP
03 : COMBO Return
04 : STACK Return