Mitsubishi Electronics QD64D2 Drums User Manual


 
7
PROGRAMMING
7.3 Programming Example when GX Configurator-CT is Used
7 - 8
1
OVERVIEW
2
SYSTEM
CONFIGURATION
3
SPECIFICATIONS
4
PROCEDURES AND
SETTINGS BEFORE
OPERATION
5
FUNCTIONS
6
UTILITY PACKAGE (GX
Configurator-CT)
7
PROGRAMMING
8
TROUBLESHOOTING
(b) Auto refresh setting
Set devices storing the present values, latch count values, overflow detection
flags, error codes, and warning codes of CH1 and CH2.
For Auto refresh setting in GX Configurator-CT, refer to Section 6.5.
Figure 7.5 Auto refresh setting screen
Table 7.3 Item on the [Initial setting] screen
Setting item Description Setting
CH1 Initial setting
Preset value setting Set preset value. 0
Coincidence output
No.1 point setting
Set these only when
the counter value
comparison function
selection (refer to
Section 4.5) is the
coincidence output
function.
10000
Coincidence output
No.1 point change
request
Change request
CH2 Initial setting
Ring counter lower limit
value
Set these only when
using the ring counter
function.
-50000
Ring counter upper limit
value
50000
Preset value setting Set preset value. -50000
CH2 continuous
comparison No.1 setting
Continuous comparison
No.1 start point setting
Set these only when
the counter value
comparison function
selection (refer to
Section 4.5) is the
continuous comparison
function.
1
Continuous comparison
No.1 repeat point
setting
2
Continuous comparison
No.1 ON time setting
10
Continuous comparison
No.1 point 1 setting
20000
Continuous comparison
No.1 point 2 setting
40000