Mitsubishi Electronics QD64D2 Drums User Manual


 
7 - 13
7.4 Programming Example when GX Configurator-CT is not Used
7
PROGRAMMING
* 1 Set this only when using the latch counter function.
* 2 Set this only when using the linear counter function.
* 3 Stores last occurred error and holds it even after error reset.
* 4 Stores last occurred warning and holds it even after error reset.
* 5 Set this only when using the coincidence output function.
* 6 Set this only when using the continuous comparison function.
Table 7.5 List of devices (continued)
Device Function
X20 CH1 count operation start signal
QX40 (X20 to X2F)
X21 CH1 count operation stop signal
X22 CH1 present value read signal
X23 CH1 preset command signal
X24
*1
CH1 latch execution command signal
X25
*1
CH1 latch count data read signal
X26
*5
CH1 coincidence output enable signal
X27
*5
CH1 coincidence LED clear signal
X28 CH1 error/warning reset command signal
X2A CH2 count operation start signal
X2B CH2 count operation stop signal
X2C CH2 present value read signal
X2D CH2 preset command signal
X2E
*6
CH2 continuous comparison execution signal
X2F CH2 error/warning reset command signal
Y30 CH1 coincidence confirmation LED signal
QY40P (Y30 to Y3F)
Y31
*2
CH1 overflow occurrence confirmation LED signal
Y32 CH2 coincidence confirmation LED signal