5.3 Using the Counter Value Comparison Function
5.3.3 Using the coincidence output test function
5 - 23
1
OVERVIEW
2
SYSTEM
CONFIGURATION
3
SPECIFICATIONS
4
PROCEDURES AND
SETTINGS BEFORE
OPERATION
5
FUNCTIONS
6
UTILITY PACKAGE (GX
Configurator-CT)
7
PROGRAMMING
8
TROUBLESHOOTING
(c) Do not turn ON the continuous comparison execution command while the
coincidence output test command is ON.
If the continuous comparison execution command is turned ON while the test
command is ON, a continuous comparison No.m execution not possible error
(Error code: 311 and 312) occurs.
POINT
Even if the coincidence output No.1 test command (Y0B) and the
coincidence output No.2 test command (Y0C) are turned ON, the counter
value coincidence No.1 (X02) and the counter value coincidence No.2
(X05) do not turn ON/OFF. (Coincidence detection interrupt also does not
occur.)
The coincidence output test function cannot be used when selecting the
coincidence output function.