POINT
(1) When another error occurs during error occurrence, take the following action.
When an error code from 100 to 500 occurs, the latest error code is
ignored and the error code stored before the latest error code is held.
When an error code from 810 to 860 occurs, the error code is overwritten
as the latest one.
(2) The error code 810 is stored for each channel, and the error code from 820 to
860 is stored for all channels.
(3) After fixing the cause of the error, reset the error by the error reset command
(Y0D). If the cause of the error is not fixed, the error is detected again.