M7CL Owner’s Manual
Functions that can be assigned to user-defined keys
280
FUNCTION PARAMETER 1 PARAMETER 2 Explanation
NO ASSIGN — — No assignment.
SCENE
INC RECALL — Recall the scene of the next existing number.
DEC RECALL — Recall the scene of the previous existing number.
DIRECT RECALL SCENE #000–#300 Directly recall the scene of the specified number.
RECALL UNDO — Execute RECALL UNDO.
STORE UNDO — Execute STORE UNDO.
TALKBACK
TALKBACK ON
LATCH Switch TALKBACK on/off.
UNLATCH Turn TALKBACK on while pressed.
SELECTED CH ASSIGN —
While holding down this key, press a SEL key of an OUTPUT chan-
nel to switch the assignment on/off. During this time, the [SEL]
LED will be lit if assign is ON, or dark if OFF.
The assignment setting made while holding down this key will be
stored. Pressing the key again will recall the stored setting. Settings
can be stored in multiple keys to facilitate rapid assignment switch-
ing.
OSCILLATOR
OSCILLATOR ON — Switch the OSC on/off.
SELECTED CH ASSIGN —
While holding down this key, press a SEL key of an OUTPUT chan-
nel to switch the assignment on/off. During this time, the [SEL]
LED will be lit if assign is ON, or dark if OFF.
CUE CLEAR — — Clear all CUE settings together.
MONITOR
MONITOR ON — Switch MONITOR on/off.
SELECTED CH ASSIGN —
While holding down this key, press the SEL key of a MIX or MATRIX
channel to switch the assignment on/off. During this time, the
[SEL] LED will be lit if assign is ON, or dark if OFF.
The assignment setting made while holding down this key will be
stored. Pressing the key again will recall the stored setting. Settings
can be stored in multiple keys to facilitate rapid assignment switch-
ing.
SOURCE SELECT
(M7CL-32/48)
STEREO L/R, MONO(C), LCR,
STIN1–4, DEFINE
Recall the selected signal to the monitor.
(M7CL-48ES)
STEREO L/R, MONO(C), LCR,
OMNI1–8, DEFINE
DIMMER ON — Switch the monitor dimmer function on/off.
MONO MONITOR — Switch MONO MONITOR on/off.
EFFECT BYPASS RACK 5–8 — Bypass the specified effect.
TAP TEMPO
CURRENT PAGE — Use the tap tempo function in the displayed screen.
RACK 5–8 — Use the tap tempo function for the specified effect.
MUTE MASTER MUTE GROUP 1–8 — Switch MUTE GROUP MASTER on/off.
METER PEAK HOLD ON — Turn the meter PEAK HOLD function on/off.
BRIGHTNESS BANK CHANGE — Toggle between the brightness settings stored in A and B.
PAGE CHANGE
PAGE BOOKMARK —
Memorize the currently selected screen (hold down the key for two
seconds or longer), or display the last-memorized screen (press
and release the key within two seconds). Popup screens can also be
memorized. In the case of a rack, the number of that rack is also
memorized.
CLOSE POPUP — Close the displayed popup window.
CH SELECT INC, DEC — Decrement the channel selection.
SEND ENCODER TO MIX/TO MATRIX —
If INPUT or ST IN is selected, swich the function of the Selected
Channel section’s send encoders from TO MIX/TO MATRIX.
SET BY SEL
SET [+48V] —
Hold down this key and press SEL to switch it on/off.
During this time, the [SEL] LED will be lit if on or dark if off.
If SET [PRE SEND] is selected, “SEND ON FADER” mode is engaged
while you are holding down the [SEL] key.
SET [Ø] —
SET [INSERT ON] —
SET [DIRECT OUT ON] —
SET [PRE SEND] —
SET [TO STEREO] —
SET [TO MONO] —
SET [TO LCR] —
Functions that can be assigned to user-defined keys