Fluke PM3370B Musical Instrument User Manual


 
6 - 16 THE CPL PROTOCOL
PROGRAM COMMUNICATION PC
Purpose:
To program baudrate, parity mode, number of data and stopbits and the
handshake method for computer communication.
After the command is sent, an <acknowledge> will be returned with the old
communication parameters still active.
If the <acknowledge> = 0, the new communication parameters will be valid
approximately 0.5 seconds later. The communication parameters are stored in
battery backup memory and restored on power-up.
This command performs the same function as the UTILITY + RS232 SETUP menu.
Command:
<baud> = 75, 110, 150, 300, 600, 1200, 2400, 4800, 9600, 19200,
38400
<parity> = O, E or N
<data bits> = 7 or 8
<stopbits> = 1
<handshake> = XONXOFF to enable Xon/Xoff handshake
HWL to enable hardwareline handshake
If left out, both handshake methods are disabled.
"PC" pds baud pds parity pds data bits
pds stop bits pds handshake CR
to bypass handshake