Yamaha 01V96i Music Mixer User Manual


 
Using the Solo Function 51
01V96i—Reference Manual
Monitoring
Using the Solo Function
You can solo and monitor Input Channels, Aux Out 1–8, and
Bus Out 1–8 using the [SOLO] buttons on the top panel.
1. Press the [DIO/SETUP] button repeatedly
until the DIO/Setup | Monitor page appears.
2. Set the SOLO parameter to On.
Set other parameters on the page, if necessary.
3. To solo and monitor Input Channels, press
the corresponding LAYER button to select a
Layer that contains the desired channels,
then press the channel [SOLO] buttons.
The channel [SOLO] button indicators and the SOLO
[SOLO] indicator light up. Only the soloed Input Chan-
nel signals are fed to the Monitor outputs.
4. To solo and monitor Output Channels, press
the LAYER [MASTER] button, then press the
channel [SOLO] buttons.
Input and Output Channels (Aux Out 1–8, Bus Out 1–8)
cannot be solo-monitored simultaneously. For example, if
you solo an Input Channel, then solo an Output Channel,
the first solo channel is cancelled.
If you solo an Output Channel first, then solo an Input
Channel, canceling the Input Channel’s solo will activate
the Output Channel’s solo.
5. You can unsolo all soloed channels by press-
ing all illuminated channel [SOLO] buttons.
The button indicators turn off. You can also unsolo all
soloed channels by pressing the SOLO [CLEAR] button.
Tip: If the SEL MODE parameter is set to Mix Solo on the
DIO/Setup | Monitor page, you can solo multiple Channels
simultaneously.