Tascam 4 Musical Instrument User Manual


 
TASCAM GigaEditor 4 Manual 159
e range is 0-127, with a default value of 60 (middle C).
Velocity scale
is value is used to scale the currently selected velocity curve in order to specify a much larger number of
lter velocity responses. For example, if you want the lter to scale from a low cuto to fully open within
the lowest velocity range, the lter response can be scaled to open more quickly by entering values above 20
(up to 127). Values below 20 will cause the lter to open more slowly over velocity yielding a darker
response. e range is 0-127 with a default value of 20. is parameter is only available when the Cuto
Controller is set to “None”.
Filter velocity response curve
Denes how the lter responds to note-on velocity.
0 - Non linear
1 - Linear
2 - Special
ese settings work in conjunction with the Velocity dynamic range parameter (see the next item).
Filter velocity response dynamic range
With this setting, you can lower or raise the dynamic range of the velocity response of
the lter. ere are ve response positions:
1 - High
2 - Medium high
3 - Medium
4 - Medium low
5 - Low
is setting works in conjunction with the Velocity curve parameter (above) as shown in the following
diagrams: