Texas Instruments TMS320C645X Musical Instrument Amplifier User Manual


 
www.ti.com
5.78PortLinkTime-OutControlCSR(SP_LT_CTL)
SRIORegisters
Figure134.PortLinkTime-OutControlCSR(SP_LT_CTL)
31-16
TIMEOUT_VALUE
RW-0xFFFFFF
LEGEND:R=Readonly;-n=valueafterreset
15-87-0
TIMEOUT_VALUEReserved
RW-0xFFFFFFR-0x00
LEGEND:R=Readonly;-n=valueafterreset
Table108.PortLinkTimeoutControlCSR(SP_LT_CTL)FieldDescriptions
BitFieldValueDescription
31-8TIMEOUT_VALUTimeoutvalueforallportsonthedevice.Thistimeoutisforlinkeventssuchassendingapacketto
EreceivingthecorrespondingACK.Maxvaluerepresents3-6seconds.Timeoutduration=205nS*
TimeoutValue;whereTimeoutvalueisthedecimalrepresentationofthisregistervalue.
FFFFFF3.4seconds
h
0FFFFF215ms
h
00FFFF13.4ms
h
000FFF839.5us
h
0000FF52.3us
h
00000F3.1us
h
000001205nsforsimulationonly
h
000000Timerdisabled
h
7-0ReservedReserved
SerialRapidIO(SRIO) 180SPRU976March2006
SubmitDocumentationFeedback