Roland M-300 DJ Equipment User Manual


 
81
4-band EQ/8-band EQ
4-band EQ/8-band EQ
GAIN knob
This adjusts the gain of each band in a range of -15.0 dB–
+15.0 dB.
Noise may occur when you operate the HPF or 4-band EQ,
but this is not a malfunction.
The function buttons have the following operations:
1.
Access the 4-BAND EQ popup.
fig.PopEQ.eps
2.
Press [F6 (FLAT)].
fig.ScrEQFlatConf.eps
A confirmation message will ask you to confirm the
operation.
3.
Press [F8 (FLAT)]; the gain of the LO, LO-MID, HI-MID, and
HI bands will be set to 0.0 dB.
If you press [F7 (CANCEL)], the operation will be cancelled.
You can recall 4-band EQ and HPF settings from the library, or
store the current 4-band EQ and HPF settings to the library.
The 4-BAND EQ LIBRARY popup is used to perform 4-band EQ
library operations.
1.
Access the 4-BAND EQ popup.
2.
Press [F4 (LIBRARY)] to access the 4-BAND EQ LIBRARY
popup.
fig.PopEQLibGuide.eps
Channel indication
This indicates the channel to which the 4-BAND EQ LIBRARY
popup applies.
Library data list
This is a list of the library data.
Recall parameter select buttons
These select the section that will be recalled.
The function buttons have the following operations:
For details on library operations, refer to “Library operations” (p.
37).
Noise may occur when you preview or recall a library item,
but this is not a malfunction.
[F1 (HPF ON)]
Turns the HPF on/off.
[F2 (EQ ON)] Turns the 4-band EQ on/off.
[F4 (LIBRARY) Accesses the 4-BAND EQ LIBRARY popup.
[F5 (PEAK CLEAR)] Clears the level meter’s peak hold or over
indication.
[F6 (FLAT)] Sets the 4-band EQ to flat response.
[F8 (CLOSE)] Closes the popup.
Setting the 4-band EQ to a flat state
5
Using the 4-band EQ library
[F2 (PREVIEW)]
Previews (auditions) the selected library data.
[F3 (NAME EDIT)] Accesses the NAME EDIT popup.
[F4 (RECALL)] Recalls the selected library data.
[F5 (STORE)] Stores the current settings into the selected
library data.
[F6 (CLEAR)] Clears the selected library data.
[F7 (LOCK)] Locks/unlocks the selected library data.
[F8 (CLOSE)] Closes the popup.
2
1
3
1
2
3
M-300_e.book 81 ページ 2010年6月24日 木曜日 午後2時26分