Korg Electric Keyboard Electronic Keyboard User Manual


 
86
7.2–1b: Master FX Chain
MFX Chain [Off, On]
Direction (Chain Direction)
[MFX1MFX2, MFX2MFX1]
Signal (Chain Signal) [LR Mix, L Only, R Only]
Level (Chain Level) [000...127]
This is the same as in Program mode. Refer to “PROG 7.2–1:
Setup.”
7.2–1c: MEQ Ctrl
MEQ Ctrl (MEQ Control Ch) [Ch01...16, G ch]
Specifies the MIDI channel that will control dynamic
modulation (Dmod) for the master EQ.
G ch: The effect will be controlled on the global MIDI chan-
nel “MIDI Channel” (GLOBAL 2.1–1a).
7.2–1d: Master EQ Gain [dB]
Low [–18.0...+18.0]
Mid [–18.0...+18.0]
High [–18.0...+18.0]
This is the same as in Program mode. (PROG 7.2–1: Setup)
7.2–1e: UTILITY
“Memory Status,” “Solo Selected Track,” “FF/REW
Speed,” “Set Location” (1.1–1d), “Select by Category”
(PROG 7.2–1d)
For details on how to select the desired utility function, refer
to “PROG 1.1–1c: UTILITY.”
Copy Master Effect
p.28 PROG 7.2–1d
Note, the MIDI control channel specified in “Control Chan-
nel” of the MFX 1 and 2 pages will not be copied.
Swap Master Effect
p.29 PROG 7.2–1d
Note, the MIDI control channel specified in “Control Chan-
nel” of the MFX 1 and 2 pages will not be swapped.
7.2–2: MFX1 (Master Effect1)
7.2–3: MFX2 (Master Effect2)
Here you can set the parameters of the “Master Effect1” and
“Master Effect2” effects that were selected in the Setup page
(
p.164–).
7.2–2(3)a: UTILITY
“Memory Status” (1.1–1d)
7.2–4: MEQ (Master EQ)
The master EQ is a three-band stereo EQ. It is used to per-
form overall equalizing (tonal adjustment) on the sound
from the L/R bus immediately before it is output to AUDIO
OUTPUT (MAIN OUT) L/MONO and R (
p.209).
7.2–4a: UTILITY
“Memory Status” (1.1–1d)
7.2–2a