Settings Common to All Modes (System Function)
Settings Common to All Modes (System Function)
Patch/Rhythm Tx Ch (Patch/Rhythm Set
Transmit Channel)
Specifies the transmit channel of MIDI messages in Patch mode. If
you do not want to transmit MIDI messages to external MIDI
devices, turn this parameter “OFF.” If you want the transmit channel
to always match the Patch/Rhythm Set Receive Channel, set this
parameter to “Rx Ch.”
Value: 1–16, Rx Ch, OFF
Remote Keyboard Sw (Remote Keyboard
Switch)
Set this parameter “ON” when you want to use an external MIDI
keyboard instead of the Fantom’s keyboard. In this case, the MIDI
transmit channel of the external MIDI keyboard can be set to any
channel. Normally you will leave this parameter “OFF.”
Turn this “ON” when you want to control the Fantom from an
external MIDI device when performing with the Arpeggiator or
RPS function (p. 39, p. 161).
Exclusive Protect (Exclusive Protect Switch)
This prevents incoming System Exclusive messages from an external
MIDI device from rewriting user memory settings. When this is set
“ON,” the data cannot be written. Value: OFF, ON
Device ID (Device ID Number)
When you want to transmit or receive System Exclusive messages,
set this parameter to match the Device ID number of the other MIDI
device.
Value: 17–32
Rx Program Change (Receive Program Change
Switch)
Specifies whether Program Change messages will be received (ON)
or not (OFF).
Value: OFF, ON
Rx Bank Select (Receive Bank Select Switch)
Specifies whether Bank Select messages will be received (ON) or not
(OFF).
Value: OFF, ON
Rx GM System On (Receive GM System On
Switch)
Specifies whether General MIDI System On messages will be
received (ON) or not (OFF).
Value: OFF, ON
Rx GM2 System On (Receive GM2 System On
Switch)
Specifies whether General MIDI 2 System On messages will be
received (ON) or not (OFF).
Value: OFF, ON
Rx GS Reset (Receive GS Reset Switch)
Specifies whether GS Reset messages will be received (ON) or not
(OFF).
Value: OFF, ON
Rx Exclusive (Receive System Exclusive Switch)
Specifies whether System Exclusive messages will be received (ON)
or not (OFF).
Value: OFF, ON
Tx Program Change (Transmit Program
Change Switch)
Specifies whether Program Change messages will be transmitted
(ON) or not (OFF).
Value: OFF, ON
Tx Bank Select (Transmit Bank Select Switch)
Specifies whether Bank Select messages will be transmitted (ON) or
not (OFF).
Value: OFF, ON
Tx Active Sensing (Transmit Active Sensing
Switch)
Specifies whether Active Sensing messages will be transmitted (ON)
or not (OFF).
Value: OFF, ON
Tx Edit Data (Transmit Edit Data Switch)
Specify whether changes you make in the settings of a patch,
multitimbre, or performance will be transmitted as system exclusive
messages (ON), or will not be transmitted (OFF).
Value: OFF, ON