Transmitting Individual Data
This data can be transmitted in one of three ways: Part parameters can be selected
from a menu and transmitted, parameters common to all Parts can be selected from a
menu and transmitted, or Insertion Effect parameters can be transmitted.
For the types of parameters which can be transmitted as Individual Data, refer to
p.150 Parameter list and operations.
* When selecting parameters common to all Parts from the menu, the following parameters can-
not be transmitted.
Device ID
MUTE Lock
EQ Lock
Rx GM On
Rx GS Reset
Transmission procedure for Part parameters
Transmission procedure for parameters common to all parts
1. Part parameters:
Press the [ALL] button to make the indicator dark.
Parameters common to all parts:
Press the [ALL] button to light the indicator.
2. Simultaneously press the PART [ll
ll
] and [rr
rr
] buttons.
3. Use [uu
uu
][dd
dd
] to select the parameter you wish to transmit.
While holding [SELECT], you can press [u][d] to jump parameters.
4. Part parameters:
Use PART[ll
ll
][rr
rr
] to select the Part which will transmit the parameter,
and use INSTRUMENT [ll
ll
][rr
rr
] to set the value.
Parameters common to all parts:
Use INSTRUMENT [ll
ll
][rr
rr
] to set the value.
5. Simultaneously press INSTRUMENT [ll
ll
] and [rr
rr
], and the data will be
transmitted.
A display of Transmitting will appear while the data is being transmitted.
* Be aware that the screen data will not be transmitted from MIDI OUT connector if MIDI
OUT/THRU Select (p.136) is set to THRU.
6. Simultaneously press PART [ll
ll
] and [rr
rr
] to end the procedure.
INSTRUMENTPAR T
LEVEL
PA N
REVERB
CHORUS
KEY SHIFT
MIDI CH
DELAY
ALL
MUTE
SC
-
55
MAP
SC
-
88
MAP
3
4
5
1
2
4
Parameters common to all Parts
6
Part Parameters
Chapter 5. Convenient functions
108