[3] Switches which can be set individually for each Part
❍ Rx Bank Sel (Bank Select Receive Switch) On/Off
To remotely select this unit sounds from another MIDI device, you can send Bank
Select messages and Program Change messages to this unit. If Rx Bank Sel is turned
on, these MIDI messages can select Variation sounds (p.20) and User sounds (p.96). If
this parameter is turned off, bank select messages will be ignored, meaning that MIDI
messages cannot select Variation sounds or User sounds (they will select Capital
sounds). If this parameter is turned off, a “_” will be displayed between the instrument
number and the Instrument name.
For details on using MIDI messages to select sounds, refer to p.126.
❍ Rx NRPN (NRPN Receive Switch) On/Off
NRPN (Non-registered Parameter Number p.132) messages allow you to modify vibrato,
filter and envelope values (p.32) via MIDI. If Rx NRPN is on, these sound parameters can
be modified by MIDI messages. If Rx NRPN is off, this will not be possible.
* When GM System On is received, Bank Select Receive Switch and NRPN Receive Switch will
be turned off.
* When GS Reset is received, Bank Select Receive Switch and NRPN Receive Switch will be
turned on.
● Procedure
1. Make sure that the [ALL] indicator is dark.
If it is lit, press the [ALL] button to turn it off.
2. Simultaneously press both the PART [ll
ll
] [rr
rr
] buttons.
3. Use PART [ll
ll
] [rr
rr
] to select the Part whose setting you wish to modify.
4. Press [uu
uu
] or [dd
dd
] to select the parameters you wish to set.
5. Use INSTRUMENT [ll
ll
] [rr
rr
] to turn on or off.
6. When you finish making settings, simultaneously press both the PART
[ll
ll
] [rr
rr
] buttons to end the procedure.
PART
INSTRUMENT
A01
100 0
LEVEL
PAN
001_Piano 1
PART
INSTRUMENT
A01
100 0
LEVEL
PAN
>Rx Bank Sel: On
INSTRUMENTPAR T
LEVEL
PA N
REVERB
CHORUS
KEY SHIFT
MIDI CH
DELAY
ALL
MUTE
SC
-
55
MAP
SC
-
88
MAP
1
2
3
4
5
6
4
Chapter 7. MIDI and the unit
141