Toro 5700-D Recording Equipment User Manual


 
Spray Pump, Agitation and Boom Control Switches
The spray pump (on/off), agitation (on/off) and boom
(on/off) control switches are located on the spray control
console (Fig. 27).
Testing
1. Make sure ignition switch is off. Remove console
panel, locate switch and unplug machine wire harness
connector from switch.
2. The switch terminals are marked as shown in Figure
28. In the ON position, continuity should exist between
terminals 2 and 3 and also between terminals 5 and 6.
In the OFF position, continuity should exist between ter-
minals 1 and 2 and also between terminals 4 and 5.
3
2
4
5
6
1
3. Terminals 7 (–) and 8 (+) are used for the indicator
Figure 27
light in the switch. The light should be illuminated when
1. Spray control console 4. RH boom switch
the switch is in the ON position.
2. Agitation switch 5. Center boom switch
3. Spray pump switch 6. LH boom switch
4. Reconnect the harness connector to the switch after
testing.
7 4 5 6
8 1 2 3
BACK OF SWITCH
Figure 28
Multi Pro 5700–D
Page 5 – 17
Electrical System
Electrical
System