Toro 5700-D Recording Equipment User Manual


 
Service and Repairs
Suction Dampener
The suction dampener is mounted to the suction line at
the spray pump (Fig. 2) and is used to dampen suction
pulses to smooth suction flow. During normal pump op
-
eration, the suction dampener diaphragm will move.
IMPORTANT: Make sure to neutralize and remove
chemicals from pump and hoses before loosening
and removing spray system components.
A damaged suction dampener diaphragm will allow a
suction leak and will cause improper pump operation. If
the diaphragm is damaged, remove diaphragm from
dampener housing and replace it (Fig. 3).
3
1
2
Figure 2
1. Spray pump 3. Suction hose
2. Suction dampener
2
4
1
3
Figure 3
1. Spray pump 3. Dampener housing
2. O–ring 4. Diaphragm
Spray System
Page 6 – 8
Multi Pro 5700–D