Starting Problems (continued)
Problem Possible Causes
Engine cranks, but does not start. Ignition switch is faulty.
Engine is malfunctioning (see Chapter 3 – Kubota
Diesel Engine).
Fuel system is malfunctioning (see Chapter 3 – Kubota
Diesel Engine).
Engine may be too cold.
Engine cranks (but should not) with the traction pedal Neutral switch is out of adjustment or faulty.
out of the neutral position.
Neutral switch wiring is faulty (see Chapter 8 –
Electrical Diagrams).
General Run Problems
Problem Possible Causes
Battery does not charge. Wiring to the charging circuit components is loose,
corroded, or damaged (see Chapter 8 – Electrical
Diagrams).
Alternator belt is slipping or damaged.
Alternator is faulty.
Battery is dead.
Engine kills during operation. Ignition switch is faulty.
Engine is malfunctioning (see Chapter 3 – Kubota
Diesel Engine).
Electrical
System
Multi Pro 5700–D
Page 5 – 5
Electrical System