Chapter 5
DA7 Users’ Guide
5
-
11
5
Channels,
Library, & Meters
[DLY] Area
The [DLY] (delay) area soft knob and data fields are seen only when channels
1 through 32 are selected.
Pressing the [DLY] area or button will disable or enable delay for
the selected channel. Use the JogDial to adjust the delay value for increased
fine tuning. You can adjust either the msec area or the sample area.The range
of the delay is from 0 to 300 msec.
You can input the values directly using the Keypad when the [10KEY
SCENE RECALL] selection in the [UTILITY>CONFIG] window is . The
input values are scrolled from right to left in the data field. To fix the value,
press the ENTER button, move the cursor, and change the screen. If the fixed
value is out of the adjustable range, the operation is cancelled. The
adjustable delay range is based on the related sampling frequency of either
48 kHz or 44.1 kHz.
When the [AUTO DISP CHANGE] selection in the [UTILITY>CONFIG]
window is , you can also display the [DYNAMICS] window by either
pressing one of the LED buttons or by adjusting one of the knobs in the
DYNAMICS/DELAY section.
See Chapter 9, Dynamics/Delay for more information.
[CH] Area
There are two parts to the [CH] (channel) area. Cursor to the or
button, and press the ENTER button to switch the channel off
or on. The fader level adjustment can be made by turning the
JogDial, after selecting the fader element with the cursor, or by
actually moving the Channel Fader to the desired level. The fader
level value is displayed in the field.
The adjustable range for the fader is -
∞
to +10dB.
OFF
ON
ON
OFF
OFF
ON
DLY Area