(S1)+5
Target station
number
Specify the target station number.
(1) Station number specification
Master station: 125 (7D
H
)
Local station, intelligent device station: 1 to 120
To increase the reliability of data, it is recommended to execute
the instruction with the execution type in (S1)+0 set to "1: With
arrival confirmation".
(2) Group specification (The target station is on a network other
than CC-Link IE Field Network.)
81
H
to A0
H
: All stations in Group No. 1 to No. 32
(It can be set when the execution type set for (S1)+0 is "0:
Without arrival confirmation".)
(3) All stations specification
FF
H
: All stations on the target station's network No. (excluding
the own station)
(It can be set when the execution type set for (S1)+0 is "0:
Without arrival confirmation".)
When using the group specification or all stations specification
• Specify 0000
H
or 03FF
H
for the target station's CPU type ((S1)+3)
( Page 156, Section 10.2.1 (5))
• The group specification cannot be used for CC-Link IE Field
Network stations.
• Writing of the data cannot be confirmed on the target station. For
whether data was written normally, check the device of the write
target station.
• Data cannot be written to the station with the station number
already in use or the station with no station number setting. Correct
the error then execute the instruction.
125 (7D
H
)
1 to 120
81
H
to A0
H
FF
H
User
(S1)+6 Unused 0User
(S1)+7
Number of
resends
During instruction execution
For the case where the instruction is not completed within the
monitoring time specified by (S1)+8, specify the number of
times the instruction is resent. (It can be set when the execution
type set by (S1)+0 is "1: With arrival confirmation".)
0 to 15 User
When the instruction is completed
The number of resends (result) is stored. (Valid when the
execution type set by (S1)+0 is "1: With arrival confirmation".)
System
(S1)+8
Arrival monitoring
time
Specify the monitoring time until instruction completion. (It can be set
when the execution type set by (S1)+0 is "1: With arrival
confirmation".)
If the instruction is not completed within the specified time, the
instruction is resent for the number of resends specified by (S1)+7.
0: 10 seconds
1 to 32767: 1 to 32767 seconds
0 to 32767 User
(S1)+9 Write data length Specify the number of words to be written.
1 to 960
To QnACPU:
1 to 480 words
User
(S1)+10 Unused 0User
Device Item Setting data Setting range Set by
Group No. 1: 81
H
Group No. 2: 82
H
Group No. 32: A0
H