275
APPENDICES
A
Appendix 3 Link Special Relay (SB) List
SB0011
Temporary error invalid
setting cancel request
Stations specified in Reserved station function disable/temporary error
invalid station setting (SW0010 to SW0017) are canceled from
temporary error invalid stations.
OFF: No request
ON: Request issued
×
SB0012
Reserved station
function disable
request
Stations specified in Reserved station function disable/temporary error
invalid station setting (SW0010 to SW0017) are temporarily canceled
from reserved stations.
OFF: No request
ON: Request issued
×
SB0013
Reserved station
specification enable
request
Stations specified in Reserved station function disable/temporary error
invalid station setting (SW0010 to SW0017) are returned to reserved
stations.
Only stations that were temporarily canceled can be returned to reserved
stations.
OFF: No request
ON: Request issued
×
SB0040
Network type (own
station)
Stores the network type of own station.
ON: Field network
SB0043 Mode (own station)
Stores the mode of own station.
OFF: Online
ON: Not online
SB0044
Station setting (own
station) (1)
This stores if the own station is a master station or not.
OFF: Not master station
ON: Master station
SB0045
Station setting (own
station) (2)
This stores if the own station is a local station or not.
OFF: Not local station
ON: Local station
(Condition)
• This is enabled when Station setting (own station) (1) (SB0044) is off.
×
SB0047
Baton pass status (own
station)
Stores the baton pass status for the own station (transient transmission
possible).
OFF: Normal
ON: Error
If an error occurs, the cause of the error can be checked by the Baton
pass status (own station) (SW0047) and Cause of baton pass
interruption (SW0048).
Depending on the timing of the link refresh, the update of Baton pass
status (own station) (SW0047) and Cause of baton pass interruption
(SW0048) may be offset by one sequence scan.
SB0049
Data link status (own
station)
Stores the own station's data link status.
OFF: Normal
ON: Error
If an error occurs, the cause of the error can be checked by Cause of
data link stop (SW0049).
Depending on the timing of the link refresh, the update of Cause of data
link stop (SW0049) may be offset by one sequence scan.
(Condition)
• This is enabled when Baton pass status (own station) (SB0047) is off.
Number Name Description
Availability
Master
station
(safety
station)
Local
station