Mitsumi electronic QS07J1GF11-T2 Drums User Manual


 
81
CHAPTER 7 PARAMETER SETTING
7
7.3 Network Configuration Setting
7.3 Network Configuration Setting
Set parameters of slave stations (the number of points and assignment of link devices) in the master station (safety
station). Also, set link scan mode and block data assurance per station.
This setting is available when "CC IE Field (Master Station [Safety])" is selected in network setting.
(1) Setting procedure
1. Configure network setting. ( Page 79, Section 7.2)
2. Open the setting window in GX Developer.
Project data list [Parameter] [Network param] [Ethernet/CC IE/MELSECNET]
button
3. Set parameters in the window.
4. Click the button.
Item Description Setting range
Assignment Method
Select a link device assignment method.
• Points/Start: Enter the points and start numbers of link devices.
• Start/End: Enter the start and end numbers of link devices.
• Points/Start
• Start/End
(Default: Start/End)
Number of PLCs
Displays the number of slave stations set for "Total Stations" in
network setting.
Station No.
Enter the number of a slave station connected to the network.
Station numbers can be set at random (cannot be duplicated).
1 to 120
(Starting from 1 (default), numbers are
displayed by the value set in "Total
stations" in network setting.)
Station Type
Select a slave station type. Select the station type same as that of the
slave station connected to the network.
• Remote I/O Station
• Remote Device Station
• Intelligent Device Station
• Local Station
(Default: Intelligent Device Station)