85
CHAPTER 7 PARAMETER SETTING
7
7.4 Network Operation Setting
7.4 Network Operation Setting
Set operating status of a network if a data link error occurs or the safety CPU module is set to STOP.
1. Configure network setting. ( Page 79, Section 7.2)
2. Open the setting window in GX Developer.
Project data list [Parameter] [Network param] [Ethernet/CC IE/MELSECNET]
button
3. Set parameters in the window.
Item Description Setting range
Parameter Name Enter the name of network operation setting parameters if desired. Up to 8 characters
Data Link Faulty Station
Setting
Select whether to hold or clear data input by standard communication
from the slave station where a data link error has occurred.
( Page 113, Section 8.2.5)
Data input by safety communication will be cleared regardless of this
setting and safety CPU operation mode.
• Turn OFF or 0 Clear Input Data
(RX/RY)
• Hold Input Data (RX/RY)
(Default: Turn OFF or 0 Clear Input
Data (RX/RY))
Output Setting During
CPU STOP
Select whether to hold or clear cyclic data output when the safety CPU
module mounted with the master/local module is set to STOP.
( Page 115, Section 8.2.6)
•Hold
• Clear (ALL OFF)
(Default: Hold)