CHAPTER 3 SPECIFICATIONS
3
3.3 Function List
3.3.2 Using the master/local module as a local station
(3) Transient transmission
(4) Diagnostic function
Function Description Reference
Communication within the same network
Transient transmission is performed to other stations using
dedicated instructions and GX Developer.
Page 152, CHAPTER 10
Communication with different networks
By setting the routing parameters (communication path) using GX
Developer in advance, transient transmission can be performed to
stations on different networks through dedicated instructions or GX
Developer. Seamless communication is available with the following
networks.
• Ethernet
• CC-Link IE Controller Network
• MELSECNET/H
• MELSECNET/10
• CC-Link (when using GX Developer)
Page 92, Section 7.7
Page 118, Section 8.3.2
Function Description Reference
CC-Link IE Field Network diagnostics
The status of CC-Link IE Field Network can be checked by GX
Developer. The faulty area, cause of the fault and its corrective
action, and event history can be checked in GX Developer.
Page 124, CHAPTER 9
Individual unit
diagnostics
Hardware test Check the internal hardware of the master/local module. Page 60, Section 6.2.1
Self-loopback test
Check the communication circuit of the transmission system of the
master/local module.
Page 62, Section 6.2.2
Own network
diagnostics
Loop test
Check the network circuit status and parameter setting status of
each station.
Page 67, Section 6.4.1
Cable test Check the connection status of the Ethernet cable. Page 74, Section 6.4.2
Other network
diagnostics
Communication test
Check whether the communication path for transient transmission
from the own station to the target station is correct.
Page 75, Section 6.4.3